The VG70 is a comprehensive transportable ICU ventilator including lung protective ventilation modes such as BIVENT and PRVC.
The VG70 has flexible configuration allowing for trolley, bed or ceiling pendant mount. As a cost effective solution the VG70 has a metal based autoclavable exhalation valve with a nonconsumable design built in flow sensor and its ventilation software is upgradeable with the available USB port.
The VG70's optimal ventilator synchrony leads to greater patient comfort, the Leak compensation system precisely controls the tidal volume of each breath delivered to the patient by adjusting compensation dosage automatically.
The VG70 is an optimal combination of invasive and non-invasive ventilator. As noninvasive ventilation is used increasingly in a wide range of clinical situations, we offer a dual solution. The VG70 combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU.
TECHNICAL SPECIFICATIONS
VCV(A/C) PCV(A/C) PRVC SIMV(VCV)+PSV
SIMV(PCV)+PSV SIMV(PRVC)+PSV SPONT/CPAP+PSV
BIVENT+PSV NIV/CPAP NIV-T NIV-S/T
Apnea Ventilation Smart Suction Manual Breath
Insp/ Exp Hold ETCO2 Measurement
Nebulization Wave form Freeze
Screen
12〞TFT color touch screen (detachable)
Supply Gas
O2, 0.28~0.6 MPa
Power Supply
AC100~240 V, 50 Hz/60 Hz
Pressure Value: Ppeak, Pplat, Pmean, Pmin, PEEP
Volume / Flow Value: Vti, Vte, MV, MVspont
Time Value: ftotal,fspont, I:E
Pressure-Time, Flow-Time, Volume-Time wave forms
Pressure-Volume, Volume-Flow, Flow-Pressure loops
FiO2, ETCO2
Calculated Values:
Compliance(C)
Resistance(R)
MVleak
RSBI
WOB
PEEPi
Paw high / low MVe high / low Circuit disconnnect
FiO2 high / low Inspiration / Expiratory tidal volume low
High Respiration Rate Apnea AC Failure Nebulizer On
Low Battery Air /O2 supply down High / Low PEEP
Leakage out of range Occlusion
PRVC and BIVENT employ lung-protective strategies, delivering intelligent ventilation
Comprehensive lung mechanics monitoring include compliance, airway resistance, PEEPi and time constant
Three waveforms & three loops with user-friendly display provide a continuous monitoring of the patient’s condition
Various ventilation modes enhance the weaning process
The unique trigger and leakage compensation system safeguard each and every patient breath resulting in smooth and comfortable breathing, avoiding extra workload on the patient and promoting recovery
RSBI and WOB provide accurate reference for weaning
Rehab Phase
Data export port provides connection to hospital monitors and Patient Data
Management Systems
Provides pressure support for the patient when spontaneous breathing is present
Upgradeable ventilation system software, with an available USB port
WARRANTY : 12 Months
Price: Rs. 2,95,000/- (Taxes Extra)
Item Code: BT-VG 70-ROYAL59.1