VENTILATORS

PORTABLE EMERGENCY VENTILATOR |

Key Features:

Model: 6000S

Price: Rs. 143000/- (Incl. All Taxes)

Warranty: 12 Months off site warranty

Code: BT-PORTVENTI-HEMO

PORTABLE VENTILATOR | AIRLOG3 | ADULT & PAEDIATRIC |

 The AIRLOG3 is an automatic oxygen respiration device(short-time ventilator) with additional inhalation facility. AIRLOG3 can control and assist Patient whose weight is more than 15Kg, as well as non-invasive and invasive mechanical ventilation. 

Product Name :AIRLOG3 Portable Home And Ambulance Ventilator

Model Name/Number :AIRLOG3

Mounting Type: Ambulance, Home, Clinic

Breathing rate:5-40 BPM

Pressure limit: 20-60 mbar

Minute volume: 3-20 LPM

Weight: 1.3 Kg

Ventilation Modes : IPPV; A/C

Patient Age Group: Adult, Paediatric

Tidal Volume :100-1500 ml

Price: 145000/- (Incl All Taxes)

Warranty: 12 months offisire warranty.

Code: BT-AIRLOG3-NIS00059


TRANSPORT VENTILATOR| LP-10| 

The Puritan Bennett LP10 is a Portable volume ventilator that runs off of a microprocessor.The ventilator has indicators that can monitor the patient’s pressure, breathing efforts, power supply, and alarms. The Puritan Bennett LP10 also can monitor the pressure limit controls which means the ventilation system can be used on pediatric patient. The Puritan Bennett LP 10 can be used in non-acute and transport situations in both pediatric and adult patients.

Specifications: Power Line     Power Usage Maximum  Nominal    External Battery  Internal Battery   110 VAC range (100-127 VAC) or 220 VAC range  (220-240 VAC), 50/60 Hz, external voltage selector switch  630 kW hours per year 315 kW hours per year Approximately 20 hours operation with 75-80 ampere-hour 12 VDC deep-cycle, gel-cell battery; approximately 10 hours with 35-40 ampere-hour 12 VDC deep-cycle, gel-cell battery Up to 1 hour operation  Type, Volume Ventilator  Motor: Brushless induction Pump    Piston, 100-2200 mL tidal volume capability  Front Panel Touch Pads  Battery Test   Front Panel Controls  Pressure Limit  Low Pressure Alarm  Alarm Silence/Reset: Push button to silence alarm or to reset; used with Battery Test button to read operating hours on Patient Pressure meter Push button to show charge level on lower window of  Patient Pressure meter  Mode: Standby, Assist/Control, SIMV or Pressure Cycle Locking knob sets pressure from 15 to 50 cmH2O, or disables limit feature 2-32 cmH2O in increments of 2 cmH2O High Pressure Alarm Limit (Assist/Control, SIMV Modes) or limit for Pressure Cycle mode 15-90 cm H2Oin increments of 5 cmH2O Volume    Push-to-turn knob from 100 to 2200 mL Breath Rate  Inspiratory Time   1-20 BPM in increments of 1 BPM and 22-38 BPM in increments of 2 BPM From 0.5 to 1.0 seconds in increments of 0.1 seconds;  166 Highland Park Dr. Bloomfield, CT 06002 U.S.A. Tel: (860) 218-2575 Fax: (860) 218-2565 Email: soma@somatechnology.com Rev 1 3/04 1.2 seconds; and 1.5-5.5 seconds in increments of 0.5 seconds Breathing Effort  Front Panel Output   Push-to-turn knob sets pressure level to detect breathing effort: -10 cmH2O to +10 cm H2O. Front Panel Input Patient Pressure: Port for connection to proximal pressure  line of patient circuit  Patient Air: 22 mm x 15 mm tube for connection to  bacteria filter.Exhalation Valve: Port for connection to exhalation valve of patient circuit  Indicators, Normal Events  Patient Pressure Meter: Displays patient pressure -10 to +100 cmH2O; can also display battery charge and machine hours of operationBreathing Effort: Green LED activated by adequate patient breathing effortPower: LEDs indicate operating power source (green AC Pwr/Batt Chg, amber External Battery, flashing amber Internal Battery)Alarms: Flashing red LEDs (Low Pressure/Apnea, Low Power,  High Pressure, Setting Error, Power Switchover)  Audible Alarms  Pulsating Tone: Low Pressure/Apnea; Low Power, High Pressure, Setting Error, Power Switchover. Steady Tone: Loss of microprocessor control. Reminder Tone: Every 5 minutes when powered by Internal Battery and each time accessory printer generates report  Rear Panel Controls  Rear Panel Inputs  Rear Panel Outputs   Maintenance  Dimensions  Weight    Resistance Factor   AC Circuit Breaker: Internal to AC power switch (1 for ON, 0 for OFF) Inlet Filter: Intake for patient air; screw-off cap for filter change. External Battery: Connection for 12 VDC battery Communication Port: Calibration information during service procedure  Vent: Cooling vent for internal ventilator components Remote Alarm: Connection for optional alarm accessories Communication Port: Connection for optional printer and digital display  Preventive maintenance by qualified professional every 6000 hours or recertification every 12 months, whichever is first  9.75" H x 14.5" W x 13.25" D (24.6 cm x 36.8 cm x 33.6 cm)  Approximately 35 lb (15.9 kg)  Less than 0.05 cmH2O/LPM  Emergency Pressure Relief  Approximately 100 cmH2O  Flow:  20-100 LPM.

PRICE: RS. 67200/- (INCL. ALL TAXES).