Brand
Aeonmed
Model Name/Number
VG70
Tidal Volume
50-2000 mL (Adult) , 20-300 mL (Child)
Ventilation Modes
VCV (NC), PCV (A/C), PRVC (A/C), SIMV (VCV/PCV/PRVC) + PSV, SPONT/CPAP + PSV, BIVENT/AP
Respiratory Rate
1-120/min
Compliance compensation
ON/OFF
Pinsp
5-70 cm H2O
Psupp
0-70 cm H2O
CPAP in NIV
2-20 cm H2O
Peep
0-35 cm H2O
PEEP in NIV
2-20 cm H2O
Phigh
5-60 cm H2O
Plow
0-35 cm H2O
Psens
-20-0 cm H2O
Vsens
0.5-20 L/min
Tube compensation (%)
0-100
Esens
5-80 %
Inspiratory time (Ti)
0.2-9 s (Adult), 0.2-5 s (Child)
Backup ventilation Tinsp
0.2-9 s (Adult), 0.2-5 s (Child)
Pause time (Tpause)
0-4 s (Adult), 0-2.5 s (Child)
Rising time (Tslope)
0-2 s
Thigh
0.2-30 s
Tlow
0.2-30 s
Frequency (f)
1-80 bpm
NIV ventilation rate
4-20 bpm (Adult), 4-40 bpm (Child)
SIMV ventilation rate
1-40 bpm
I:E ratio
1:10-4:1
Nebulizer time
30 min or 45 min
Dimension (main unit)
322x375x366 mm
Main unit weight
12.5 kg
Cart weight
25 kg
Screen size
12 Inch color touch screen
Minimum Order Quantity
01
Product Details:-
VG70 is a critical care ventilator suitable for intra-hospital transport and sub-acute care of infants, children and adults. VG70 combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator. It has comprehensive functionality and a userfriendly design. VG70's internal turbine provides needed air pressure with a low sound level and, along with its internal batteries, prepare it fully for mobile use.
Superior Mobile ICU ventilator
Comprehensive ICU ventilator including BIVENT and PRVC
Compact, big capacity battery, no air compressor, intra-hospital mobility
Flexible device configuration: equipped on a trolley, bed or ceiling pendant
Cost Effective Solution
Unique metal-based, autoclavable, heated exhalation valve
Built-in flow sensor, non-consumable design
Upgradeable ventilation system software, with an available USB port
Optimal patient-ventilator synchrony, increase patient comfort
The Unique Leak Compensation System - Keep precise control on the tidal volume of eac breath delivered to the patient by adjusting compensation dosage automatically
Advanced Trigger Technique - Enhance sensitivity, avoid spurious triggering Safe Ventilation Through Whole Treatment Phase
Initial Treatment Phase
Noninvasive ventilation mode associated with decreased intubation rates, shortened patient stays, improved patient comfort, and a reduced risk of cross infection
Preset patient's height and IBW. Reduce clinician's workload
Stable Condition Phase
PRVC and BIVENT employ lung-protective strategies, delivering intelligent ventilation
Comprehensive lung mechanics monitoring include compliance, air way resistance, PEEPi and time constant
Three waveforms & three loops with user-friendly display provide a continuous monitoring of the patient's condition
Weaning Phase
Various ventilation modes enhance the weaning process
The unique trigger and leakage compensation system safeguards each and every patient breath resulting in smooth and comfortable breathing, avoiding extra workload on the patient and promoting recovery
RSBI and WOB provide accurate reference for weaning
Rehab Phase
Data export port provides connection to hospital monitors and Patient Data Management Systems
Provides pressure support for the patient when spontaneous breathing is present
Warranty:
12 Months Free AMC
Price: 6,90,000/- (Incl. Taxes)
Item Code:
BT-VG70-TED